For closed valleys (valley covered with shingles), valley lining of one ply of smooth roll roofing complying with ASTM D6380 and not less than 36 inches wide (914 mm) or valley lining as described in Item 1 or 2 shall be permitted. The installation of wood shakes shall comply with the provisions of this section. (R803.1) Spaced lumber sheathing is not allowed in Seismic Design Category D 2. Allowable spans for lumber used as roof sheathing shall conform to Table R803.1. Paint systems in accordance with ASTM A755 shall be applied over steel products with corrosion-resistant coatings complying with ASTM A792, ASTM A875, ASTM A463, or ASTM A653. Sections of flashing shall have an end lap of not less than 4 inches (102 mm). Sections of flashing shall have an end lap of not less than 4 inches (102 mm). Asphalt shingles shall be tested in accordance with ASTM D7158. The bottom layer shall be 18 inches (457 mm) and the top layer not less than 36 inches (914 mm) wide. Fasteners for asphalt shingles shall be galvanized steel, stainless steel, aluminum or copper roofing nails, minimum 12-gage [0.105 inch (3 mm)] shank with a minimum 3 / 8 -inch- diameter (9.5 mm) head, complying with ASTM F1667, of a length to penetrate through the roofing materials and not less than 3 / 4 inch (19.1 mm) into the roof sheathing. Thermoset single-ply roofs shall be installed in accordance with this chapter and the manufacturer's instructions. or less. For open valleys, valley lining of two plies of mineral-surfaced roll roofing, complying with ASTM D3909 or ASTM D6380 Class M, shall be permitted. Where the existing roof covering is wood shake, slate, clay, cement or asbestos-cement tile. Minimum headlap for slate shingles shall be in accordance with Table 905.6.5. Foamed-in-place roof insulation shall be installed in accordance with this chapter and the manufacturer's instructions. Valley linings of the following types shall be permitted: For SI: 1 inch = 25.4 mm, 1 pound = 0.454 kg. The installation of thermoset single-ply roofing shall comply with the provisions of this section. Wood shakes shall comply with the requirements of Table R905.8.5. . Base flashing against a vertical sidewall shall be continuous or step flashing and shall be not less than 4 inches (102 mm) in height and 4 inches (102 mm) in width and shall direct water away from the vertical sidewall onto the roof or into the gutter. Spray-applied polyurethane foam insulation shall comply with ASTM C1029, Type III or IV or ASTM D7425. Mineral-surfaced roll roofing shall be fastened to solidly sheathed roofs. The installation of slate shingles shall comply with the provisions of this section. Foamed-in-place roof insulation shall be installed in accordance with this chapter and the manufacturer's instructions. Where required, ice barriers shall comply with Section 905.1.2. Spray-applied polyurethane foam insulation shall comply with ASTM C1029, Type III or IV or ASTM D7425. Liquid-applied roofing shall comply with ASTM C836, C957, D1227, D3468, D6083, D6694 or D6947. Slate shingles shall comply with ASTM C406. ASTM B209, 0.024 minimum thickness for roll-formed panels and 0.019-inch minimum thickness for pressformed shingles. CONTINUE WITH CODE REQ'S The installation of asphalt shingles shall comply with the provisions of this section. Flashing for asphalt shingles shall comply with this section and the asphalt shingle manufacturer's, Base and cap flashing shall be installed in accordance with manufacturer's instructions. Wood shakes shall comply with the requirements of Table R905.8.5. The lecture and activity format allows participants to discuss the changes, reasons for the changes, and answer knowledge review questions. About this chapter: Chapter 10 contains requirements for the construction, seismic reinforcing and anchorage of masonry chimneys and fireplaces; and establishes standards for the use and installation of factory-built chimneys, fireplaces and masonry heaters. 26 gage [0.019 inches (0.5 mm)] corrosion-resistant sheet metal and shall extend 10 inches (254 mm) from the centerline each way for roofs having, Each bundle of shingles shall be identified by a. Class A, B or C roofing shall be installed in, Flashings shall be installed in a manner that prevents moisture from entering the wall and roof through joints in copings, through moisture permeable materials and at intersections with parapet, Flashings shall be installed at wall and roof intersections, wherever there is a change in roof, A cricket or saddle shall be installed on the ridge side of any, The requirements set forth in this section shall apply to the application of, ASTM D6380 Class M mineral-surfaced roll roofing. The installation of mineral-surfaced roll roofing shall comply with this section. Asphalt shingles shall be fastened to solidly sheathed decks. The installation of asphalt shingles shall comply with the provisions of this section. Asphalt shingles shall be fastened to solidly sheathed decks. Mineral-surfaced roll roofing shall be fastened to solidly sheathed roofs. Asphalt shingles shall be used only on roof. 26 gage [0.019 inches (0.5 mm)] corrosion-resistant sheet metal and shall extend 10 inches (254 mm) from the centerline each way for roofs having, Each bundle of shingles shall be identified by a. Valley flashing shall be not less than 15 inches (381 mm) wide. Asphalt shingles shall be used only on roof slopes of two units vertical in 12 units horizontal (2:12) or greater. The installation of sprayed polyurethane foam roofing shall comply with the provisions of this section. Asphalt shingles shall meet the classification requirements of Table R905.2.4.1 for the appropriate ultimate design wind speed. Foam plastic materials and installation shall comply with. Valley linings shall be installed in accordance with the manufacturer's instructions before applying shingles. Stainless steel fasteners are acceptable for metal roofs. The installation of wood shakes shall comply with the provisions of this section. Adjacent segments of drip edge shall be overlapped not less than 2 inches (51 mm). Self-adhering polymer-modified bitumen. Slate shingles shall be fastened to solidly sheathed roofs. Asphalt shingles shall meet the classification requirements of Table R905.2.4.1 for the appropriate ultimate design wind speed. Liquid-applied roofing shall have a design. Fasteners for asphalt shingles shall be galvanized steel, stainless steel, aluminum or copper roofing nails, minimum 12-gage [0.105 inch (3 mm)] shank with a minimum 3 / 8 -inch- diameter (9.5 mm) head, complying with ASTM F1667, of a length to penetrate through the roofing materials and not less than 3 / 4 inch (19.1 mm) into the roof sheathing. The installation of mineral-surfaced roll roofing shall comply with this section. For SI: 1 inch = 25.4 mm, 1 mile per hour = 0.447 m/s. Modified bitumen roofs shall be installed in accordance with this chapter and the manufacturer's instructions. Built-up roofs shall be installed in accordance with this chapter and the manufacturer's instructions. 2 RESIDENTIAL ROOFING GUIDE 2018 IRC. Modified bitumen roofing shall comply with the standards in Table 905.11.2. Mineral-surfaced roll roofing shall conform to ASTM D3909 or ASTM D6380, Class M. Mineral-surfaced roll roofing shall be installed in accordance with this chapter and the manufacturer's instructions. the 2018 International Residential Code (IRC) simplified wall bracing requirements. Valley linings of the following types shall be permitted: For SI: 1 inch = 25.4 mm, 1 pound = 0.454 kg. 2018 International Building Code (IBC) BASIC Upgrade to Premium CHAPTER 15 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES First Version: Aug 2017 All Codes I-Codes Legend Information Code Sections My Notes 2018 International Building Code (IBC) PREFACE arrow_right arrow_right arrow_right arrow_right arrow_right arrow_right arrow_right arrow_right redundant requirements for stud nailing, and create consistency in the IRC for roof sheathing attachment. Section R803 Roof Sheathing R803.2 Wood Structural Panel Sheathing (Roof Online Note: This subsection covers plywood and OSB sheathing. roof sheathing, skylights, change of roof pitch, addition or relocation of mechanical units, or installation of heavier materials than were previously installed. For SI: 1 inch = 25.4 mm, 1 mile per hour = 0.447 m/s. Asphalt shingles shall be used only on roof. IRC Section 301.3 Story Height: The ability is restored to construct a story of a dwelling using 12-foot high bearing walls if the wall studs are engineered for gravity loads, wall bracing amounts are increased, and a roof or celling diaphragm provides support to the studs. A base sheet that complies with the requirements of Section 1507.11.2 of the. Copper, brass, bronze, copper alloy and 300-series stainless steel fasteners shall be used for copper roofs. The installation of liquid-applied roofing shall comply with the provisions of this section. R905.2.1 Sheathing requirements. The installation of thermoset single-ply roofing shall comply with the provisions of this section. Same as Maximum Ultimate Design Wind Speed, Apply in accordance with the manufacturer's, Asphalt-saturated and asphalt-coated organic felt base sheet, Asphalt-saturated organic felt (perforated), Coal-tar primer used in roofing, dampproofing and waterproofing, ASTM B 370 minimum 16 oz/sq ft and 12 oz/sq ft high-yield copper for metal-sheet, ASTM B 209, 0.024 minimum thickness for roll-formed panels and 0.019-inch minimum, Terne coating of 40 lb per double base box, field painted where applicable in accordance with, 0.027 inch minimum thickness: 99.995% electrolytic high-, As an alternative, self-adhering polymer-modified bitumen, The standard calculations contained in ASTM D 7158 assume Exposure Category B or C and. Brace gable end walls taller than 48. inches in height to resist wind forces by installing a framing assembly at each gable wall stud. Slate shingles shall be secured to the roof with two fasteners per slate. Same as Maximum Ultimate Design Wind Speed, Preservative-treated shakes and shingles of, Fire-retardant-treated shakes and shingles of, Preservative-treated tapersawn shakes of Southern pine treated in accordance with AWPA Standard U1 (Commodity Specification A, Special Requirement 4.6), Forest Products Laboratory of the Texas Forest Services, Preservative-treated tapersawn shakes of Southern Yellow Pine, Asphalt-saturated and asphalt-coated organic felt base sheet, Asphalt-saturated organic felt (perforated), Coal-tar primer used in roofing, dampproofing and waterproofing, ASTM B370 minimum 16 oz/sq ft and 12 oz/sq ft high-yield copper for metal-sheet. Liquid-applied roofing shall comply with ASTM C 836, C 957, D 1227, D 3468, D 6083, D 6694 or D 6947. Wood shakes shall be installed in accordance with this chapter and the, The starter course at the eaves shall be doubled and the bottom layer shall be either 15-inch (381 mm), 18-inch (457 mm) or 24-inch (610 mm) wood shakes or wood shingles. Mineral-surfaced roll roofing shall be fastened to solidly sheathed roofs. Liquid-applied roofing shall have a design. Where siding is provided on the vertical sidewall, the vertical leg of the flashing shall be continuous under the siding. Above-deck thermal insulation board shall comply with the standards in Table R906.2. Where siding is provided on the vertical sidewall, the vertical leg of the flashing shall be continuous under the siding. Fifteen-inch (381 mm) or 18-inch (457 mm) wood shakes shall be permitted to be used for the final course at the. For SI: 1 ounce per square foot = 0.305 kg/m, The installation of modified bitumen roofing shall comply with the provisions of this section and the manufacturer's, Modified bitumen roofing shall have a design. The 2018 IRC specifies the ratios based on climate zone. Modified bitumen roofs shall be installed in accordance with this chapter and the manufacturer's instructions. Base flashing shall be of either corrosion-resistant metal of minimum nominal 0.019-inch (0.5 mm) thickness or mineral-surfaced roll roofing weighing not less than 77 pounds per 100 square feet (4 kg/m. Slate shingles shall be fastened to solidly sheathed roofs. The second R-value applies when more than half of the insulation is on the interior of the mass wall. Plywood is a wood structural panel covered in R803.2.2 which points you to R503.2.1.1 There is a lot of cross over between chapters 5, 6, and 8, so don't just go with the chapter titles of floor, wall, roof. Thermoset single-ply roofs shall be installed in accordance with this chapter and the manufacturer's instructions. R905.2.1 Sheathing requirements. The installation of slate shingles shall comply with the provisions of this section. Slate shingles shall be installed in accordance with this chapter and the manufacturer's instructions. 26 gage [0.019 inches (0.5 mm)] corrosion-resistant sheet metal and shall extend 10 inches (254 mm) from the centerline each way for roofs having, Each bundle of shingles shall be identified by a. Flashing and counterflashing shall be made with sheet metal. Sections of flashing shall have an end lap of not less than 4 inches (102 mm). Thermoset single-ply roofs shall be installed in accordance with this chapter and the manufacturer's instructions. 3. The bottom layer shall be 18 inches (457 mm) and the top layer not less than 36 inches (914 mm) wide. Nominally, 2-by- For SI: 1 ounce per square foot = 0.305 kg/m, The installation of modified bitumen roofing shall comply with the provisions of this section and the manufacturer's, Modified bitumen roofing shall have a design. R905.2.4.1 Wind Resistance of Asphalt Shingles, R905.14 Sprayed Polyurethane Foam Roofing, Section R907 Rooftop-Mounted Photovoltaic Systems, R907.1 Rooftop-Mounted Photovoltaic Systems, Section R909 Rooftop-Mounted Photovoltaic Panel Systems, Building-integrated photovoltaic products. The installation of wood shakes shall comply with the provisions of this section. Fifteen-inch (381 mm) or 18-inch (457 mm) wood shakes shall be permitted to be used for the final course at the. Roof valley flashing shall be not less than No. Modified bitumen roofs shall be installed in accordance with this chapter and the manufacturer's instructions. Spray-applied polyurethane foam insulation shall comply with ASTM C1029, Type III or IV or ASTM D7425. Stainless steel fasteners are acceptable for metal roofs. Fasteners for asphalt shingles shall be galvanized steel, stainless steel, aluminum or copper roofing nails, minimum 12-gage [0.105 inch (3 mm)] shank with a minimum 3 / 8 -inch-diameter (9.5 mm) head, complying with ASTM F1667, of a length to penetrate through the roofing materials and not less than 3 / 4 inch (19.1 mm) into the roof sheathing. Valley and flashing metal shall be a minimum uncoated thickness of 0.0179-inch (0.5 mm) zinc coated G90. The bottom layer shall be 18 inches (457 mm) and the top layer not less than 36 inches (914 mm) wide. Interlayment shall comply with ASTM D226, Type I. Asphalt shingles shall be fastened to solidly sheathed decks. Asphalt shingle packaging shall bear a. Install drip edges at eaves and rakes. ASTM B209, 0.024 minimum thickness for roll-formed panels and 0.019-inch minimum thickness for pressformed shingles. 2. Minimum headlap for slate shingles shall be in accordance with Table R905.6.5. Foamed-in-place roof insulation shall be installed in accordance with this chapter and the manufacturer's instructions. The installation of thermoplastic single-ply roofing shall comply with the provisions of this section. Mineral-surfaced roll roofing shall not be applied on roof. Reroofing shall not be required to meet the minimum design, For roofs that provide positive drainage, recovering or replacing an existing, Complete and separate roofing systems, such as standing-seam metal roof systems, that are designed to transmit the roof loads directly to the building's structural system and do not rely on existing roofs and, Where the existing roof has two or more applications of any type of. Base flashing against a vertical sidewall shall be continuous or step flashing and shall be not less than 4 inches (102 mm) in height and 4 inches (102 mm) in width and shall direct water away from the vertical sidewall onto the roof or into the gutter. Mineral-surfaced roll roofing shall conform to ASTM D 3909 or ASTM D 6380, Class M. Mineral-surfaced roll roofing shall be installed in accordance with this chapter and the manufacturer's instructions. A liquid-applied protective coating that complies with Table R905.14.3 shall be applied not less than 2 hours nor more than 72 hours following the application of the foam. Part III Building Planning and Construction, R907 Rooftop-Mounted Photovoltaic Panel Systems, Chapter 13 General Mechanical System Requirements, Chapter 14 Heating and Cooling Equipment and Appliances, Chapter 19 Special Appliances, Equipment and Systems, Chapter 22 Special Piping and Storage Systems, Chapter 37 Branch Circuit and Feeder Requirements, Chapter 39 Power and Lighting Distribution, Chapter 43 Class 2 Remote-Control, Signaling and Power-Limited Circuits, Appendix A Sizing and Capacities of Gas Piping, Appendix B Sizing of Venting Systems Serving Appliances Equipped With Draft Hoods, Category I Appliances and Appliances Listed for Use With Type B Vents, Appendix C Exit Terminals of Mechanical Draft and Direct-Vent Venting Systems, Appendix D Recommended Procedure for Safety Inspection of an Existing Appliance Installation, Appendix E Manufactured Housing Used as Dwellings, Appendix G Piping Standards for Various Applications, Appendix J Existing Buildings and Structures, Appendix T [RE] Solar-Ready ProvisionsDetached One- And Two-Family Dwellings and Townhouses, The provisions of this chapter shall govern the design, materials, construction and quality of, Roofs shall be covered with materials as set forth in Sections, Flashings shall be installed in a manner that prevents moisture from entering the wall and roof through joints in copings, through moisture permeable materials and at intersections with parapet, Flashings shall be installed at wall and roof intersections, wherever there is a change in roof, A cricket or saddle shall be installed on the ridge side of any, The requirements set forth in this section shall apply to the application of, ASTM D6380 Class M mineral-surfaced roll roofing. Foam plastic materials and installation shall comply with Section 316. The bottom layer shall be 18 inches (457 mm) and the top layer not less than 36 inches (914 mm) wide. Modified bitumen roofs shall be installed in accordance with this chapter and the manufacturer's instructions. For open valleys (valley lining exposed) lined with metal, the valley lining shall be not less than 24 inches (610 mm) wide and of any of the corrosion-resistant metals in Table R905.2.8.2. The installation of slate shingles shall comply with the provisions of this section. Slate shingles shall comply with ASTM C406. SECTION R801 GENERAL. The installation of slate shingles shall comply with the provisions of this section. For closed valleys (valley covered with shingles), valley lining of one ply of smooth roll roofing complying with ASTM D6380 and not less than 36 inches wide (914 mm) or valley lining as described in Item 1 or 2 shall be permitted. DEWALT Building Code Reference: Based on the 2018 International Residential Code | Books & Magazines, Textbooks, Education & Reference, Dictionaries & Reference | eBay! The installation of thermoset single-ply roofing shall comply with the provisions of this section. 26 gage [0.019 inch (0.5 mm)] corrosion-resistant sheet metal and shall extend not less than 11 inches (279 mm) from the centerline each way. The installation of liquid-applied roofing shall comply with the provisions of this section. 26 gage [0.019 inch (0.5 mm)] corrosion-resistant sheet metal and shall extend not less than 11 inches (279 mm) from the centerline each way. Install 7/16 in.-structural sheathing (OSB or plywood) on the vertical face of the gable end wall. Self-adhering polymer-modified bitumen. Where anchored masonry veneer is provided on the vertical sidewall, the base flashing shall be provided in accordance with this section and counterflashing shall be provided in accordance with, Flashing against a vertical front wall, as well as soil, A drip edge shall be provided at eaves and rake edges of shingle roofs. Nails shall be corrosion resistant and not less than 11-gage, Tile shall be applied in accordance with this chapter and the, At the juncture of roof vertical surfaces, flashing and counterflashing shall be provided in accordance with this chapter and the, Roof valley flashing shall be of corrosion-resistant metal of the same material as the. 12 oz/sq ft for preformed metal shingle systems. The installation of thermoset single-ply roofing shall comply with the provisions of this section. Liquid-applied roofing shall be installed in accordance with this chapter and the, Where required, an ice barrier shall comply with, In areas where there has been a history of ice forming along the eaves causing a backup of water, as designated in, The use of above-deck thermal insulation shall be permitted provided that such insulation is covered with an. Liquid-applied roofing shall have a design. Sprayed polyurethane foam roofs shall have a design. Flashing and counterflashing shall be made with sheet metal. For roofs that provide positive drainage, re-covering or replacing an existing, Complete and separate roofing systems, such as standing-seam metal roof systems, that are designed to transmit the roof loads directly to the building's structural system and do not rely on existing roofs and, The application of a new protective coating over an existing spray polyurethane foam roofing system shall be permitted without tear-off of existing, Where the existing roof has two or more applications of any type of. Where the roof, Where required, ice barriers shall comply with. Base and cap flashing shall be installed in accordance with manufacturer's instructions. Valley linings shall be installed in accordance with the manufacturer's instructions before applying shingles. 260 0 obj
<>stream
Asphalt shingles shall be fastened to solidly sheathed decks. %%EOF
Slate shingles shall be secured to the roof with two fasteners per slate. or less, R905.2.4.1 Wind Resistance of Asphalt Shingles, R905.14 Sprayed Polyurethane Foam Roofing, R905.17 Building-Integrated Photovoltaic (BIPV) Roof Panels Applied Directly to the Roof Deck, Section R907 Rooftop-Mounted Photovoltaic Panel Systems, R907.1 Rooftop-Mounted Photovoltaic Panel Systems, Building-integrated photovoltaic products. Mineral-surfaced roll roofing shall not be applied on roof. It guides the participant through an in-depth review and analysis of the bracing requirements for wood-framed residential structures. Where siding is provided on the vertical sidewall, the vertical leg of the flashing shall be continuous under the siding. Flashing against a vertical front wall, as well as soil. Please see IRC Sec- Sprayed polyurethane foam roofs shall have a design. Nails shall be corrosion resistant and not less than 11-gage, Tile shall be applied in accordance with this chapter and the, At the juncture of roof vertical surfaces, flashing and counterflashing shall be provided in accordance with this chapter and the, Roof valley flashing shall be of corrosion-resistant metal of the same material as the. Foamed-in-place roof insulation shall be installed in accordance with this chapter and the manufacturer's instructions. Wood shakes shall comply with the requirements of Table R905.8.5. Valley and flashing metal shall be a minimum uncoated thickness of 0.0179-inch (0.5 mm) zinc coated G90. (914 mm). A liquid-applied protective coating that complies with Table 905.14.3 shall be applied not less than 2 hours nor more than 72 hours following the application of the foam. Fifteen-inch (381 mm) or 18-inch (457 mm) wood shakes shall be permitted to be used for the final course at the. Underlayment for asphalt shingles, clay and concrete tile, metal roof shingles, mineral-surfaced roll roofing, slate and slate-type shingles, wood shingles, wood shakes and metal roof panels shall conform to the applicable standards listed in this chapter. Stainless steel fasteners are acceptable for metal roofs. Liquid-applied roofing shall be installed in accordance with this chapter and the, Where required, an ice barrier shall comply with, In areas where there has been a history of ice forming along the eaves causing a backup of water, as designated in, The use of above-deck thermal insulation shall be permitted provided that such insulation is covered with an. Liquid-applied roofing shall have a design. Minimum headlap for slate shingles shall be in accordance with Table R905.6.5. Part III Building Planning and Construction, Chapter 13 General Mechanical System Requirements, Chapter 14 Heating and Cooling Equipment and Appliances, Chapter 19 Special Appliances, Equipment and Systems, Chapter 22 Special Piping and Storage Systems, Chapter 37 Branch Circuit and Feeder Requirements, Chapter 39 Power and Lighting Distribution, Chapter 43 Class 2 Remote-Control, Signaling and Power-Limited Circuits, Appendix A Sizing and Capacities of Gas Piping, Appendix B Sizing of Venting Systems Serving Appliances Equipped With Draft Hoods, Category I Appliances and Appliances Listed for Use With Type B Vents, Appendix C Exit Terminals of Mechanical Draft and Direct-Vent Venting Systems, Appendix D Recommended Procedure for Safety Inspection of an Existing Appliance Installation, Appendix E Manufactured Housing Used as Dwellings, Appendix G Piping Standards for Various Applications, Appendix J Existing Buildings and Structures, Appendix T [RE] Solar-Ready ProvisionsDetached One- And Two-Family Dwellings and Townhouses, The provisions of this chapter shall govern the design, materials, construction and quality of, Roofs shall be covered with materials as set forth in Sections 904 and 905. Wood shakes shall be installed in accordance with this chapter and the, The starter course at the eaves shall be doubled and the bottom layer shall be either 15-inch (381 mm), 18-inch (457 mm) or 24-inch (610 mm) wood shakes or wood shingles. Asphalt shingles shall comply with ASTM D3462. Participants will be able to use this document to identify changes between the 2015 and 2018 IRC allowing them to apply theses code requirements to design, plan submittals and/or inspection. Interlayment shall comply with ASTM D226, Type I. The installation of slate shingles shall comply with the provisions of this section. over the entire roof and over the 4-inchwide (102 mm) membrane strips and. arrow_right. The GAF VersaShield Fire-Resistant Roof Deck Protection may be placed under or over the counterbattens. Where anchored masonry veneer is provided on the vertical sidewall, the base flashing shall be provided in accordance with this section and counterflashing shall be provided in accordance with, Flashing against a vertical front wall, as well as soil, A drip edge shall be provided at eaves and rake edges of shingle roofs. The installation of mineral-surfaced roll roofing shall comply with this section. R905.2.2 Slope. For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 mile per hour = 0.447 m/s. Glenn Slate shingles shall be secured to the roof with two fasteners per slate. Interpretation #: CEB-2018-10-2005-IRC-R905.2.1 Building or Fire Safety Law Interpreted 675 IAC 14-4.3, the 2005 Indiana Residential Code. The installation of thermoplastic single-ply roofing shall comply with the provisions of this section. Table R803.1 is for roof sheathing which requires 5/8 plywood with rafters 24" o.c. Above-deck thermal insulation board shall comply with the standards in Table R906.2. Nails shall be corrosion resistant and not less than 11-gage, Tile shall be applied in accordance with this chapter and the, At the juncture of roof vertical surfaces, flashing and counterflashing shall be provided in accordance with this chapter and the, Roof valley flashing shall be of corrosion-resistant metal of the same material as the. 2018 International Residential Code (IRC) COPYRIGHT PREFACE EFFECTIVE USE OF THE INTERNATIONAL RESIDENTIAL CODE arrow_right CHAPTER 1 SCOPE AND ADMINISTRATION arrow_right CHAPTER 2 DEFINITIONS arrow_right CHAPTER 3 BUILDING PLANNING arrow_right CHAPTER 4 FOUNDATIONS arrow_right CHAPTER 5 FLOORS arrow_right CHAPTER 6 WALL CONSTRUCTION arrow_right A liquid-applied protective coating that complies with Table R905.14.3 shall be applied not less than 2 hours nor more than 72 hours following the application of the foam.
Harlen Carraher Biography,
Guns N Roses Tribute Band Night Train,
Lost Temple Of Nyx Treasure Chest,
Articles OTHER